Type | |
SPD secundum EN 61643-31 / IEC 61643-31 | type 1+2 / classis I+II |
Maximilianus.continuum operativum DC voltage (DC+)-PE,(DC-)-PE ,(DC+)-(DC-) Ucpv | 1500 V DC |
Nominalis missio currentis (8/20μs) In | 20 kA |
Maxima missio currentis (8/20μs) Imax | 40 KA |
Maximus impetus currentis (8/20μs) Itotal | 40 KA |
Maximus impetus currentis (10/350μs) Iimp* | 6.25 kA |
Maximus impetus currentis (10/350μs) Itotal | 12.5 kA |
continua current ad PV applicationem ICPV | 0.2 mA |
Intentio tutelae (DC+)-PE,(DC-)-PE(DC+)-(DC-) U*p | 5.0 kV |
Responsum tempus t *A | 25 us (LN) |
Brevis Circuitus Current Rating Iscpv | 2000 A |
Residua vena ac et dc IPE | 0.3 mA(DC), 0.3 mA(AC); |
Umor range | 5% ... 95% |
Teli operating temperaturis TU | -40°C ... +70°C |
Atmosphaerae pressura et altitudo | 80k Pa ... 106k Pa, -500 m ... 2000 m |
Status operating / culpa indicium | Viridi ok / Rubrum defectus |
Numerus portuum | Portus unus |
Cross-sectional area (max.) | 2 AWG (Solidus, Stranded) / 4 AWG (flexibile) 35 mm2 ( Solidum , Stranded ) / 25 mm2 ( Flexibile ) . |
Ad ornatum | 35 mm DIN rail ace.ad EN 60715 |
Claude materia | thermoplastic |
Locum institutionem | amet institutionem |
Gradus praesidium | IP 20 |
capacitas | 4 moduli(s), DIN 43880 |
Approbationes | - |
Genus remotis significat contactum | changeover contactu |
ac commutatione facultatem | 250V / 0.5 A |
de commutatione facultatem | 250V/ 0.1 A;125 V/0.2 A;75 V / 0.5 A |
Crucis-Lorem area pro remotis significat terminales | max.1.5 mm2solidum / flexibile |
Remotis significat terrorem modus | Normal: clausus;defectum: aperta circuitu |
Accessibility | inaccessibilis |
Praesidium adjuncti | Overcurrent |
PV systema terrestris | aggerari et eruta (utrumque) |
ABSOLUTORUM MULTIPLICATIONE defectum modus (OCFM / SCFM) | OCFM |
Productum hoc solum institui potest et a professionalibus idoneis conservari.Institutionem positio manibus attingi non potest.Fac ut impotentia sit et vide num SPD totum ante institutionem ius sit.Si damnum vel fenestra ostentationis rubra est, SPD amplius adhiberi non potest;Si fenestra viridis est, SPD normale est.
Institutio SPD fig.3 IEC 60364-5-53 innitenda est.Area sectionis transversalis filum humile non minus quam 4 mm2 esse debet, et longitudo totalis plumbi non plus quam 0.5m.
Minima distantia ab aliqua superficie conductiva aggerari ad quam SPD institui potest, est 8mm.
Connexio remotae significationis terroris: SPD providetur remotis interfaces significationibus (NC, COM et NO, normaliter occlusis), applicabilis pro remotis vigilantiae vel terroris centralised.
Post nexum, siste si modulus adaptatur. Si ita, NC et COM clauduntur;sin minus, modulum reprime.